Why a Warfarin Interaction Study Measured Drug Levels and INR

Illustration of a printed chromatogram beside a sample vial and pen

Written by

in

A drug concentration and a clotting test measure different things. In a set of phase 1 interaction studies involving obeticholic acid, investigators measured both to see how coadministration affected warfarin exposure and response.

Two kinds of measurements

Researchers used a fixed-sequence design in healthy adults. They measured plasma concentrations of the warfarin enantiomers and tracked clotting endpoints, including the international normalized ratio (INR). The paper reported no substantial effect on S-warfarin exposure and described modest reductions in the maximum INR response under the tested conditions.

Why the endpoints belong in separate columns

A drug-level comparison asks how exposure changed. INR addresses a physiological response under the study regimen. The results should be reported with their dose, time frame and subject population. A fixed-sequence healthy-volunteer study does not establish the response of an individual receiving long-term therapy.

Edwards et al., Advances in Therapy (2017)